ASTM B280 ACR Copper Tube

ASTM B280 ACR Copper Tube

Standard Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service

ASTM B280 establishes the requirements for seamless copper tube intended for sue in the connection, repaires, or alternations of air conditioning or refrigeration units in the field.

The copper fittings used for soldered or brazed connections in air conditioning and refrigeration systems are described in ASME B16.22.

ASTM B280 copper tube shall be produced from C10200, C12000 or C12200, and the copper tube manufacturer has the option to supply any one of them.

Copper UNS No.Previously Used DesignationDescription
C10200OFOxygen free without residual deoxidants
C12000DLPPhosphorus dexidized, low residual phosphorus
C12200DHPPhosphorus dexidized, high residual phosphorus

Normally Winland supply ASTM B280 copper tubes of C12200 UNS designation, which contains copper + silver at 99.9% of weight, and contains phosphorus at 0.015~0.040% of weight.

Cleanness of copper tube

  • Soft coiled lengths copper tube: Interior surface residue limit is 0.0035-g/ft2 (0.038 g/m2)
  • Straigtht lengths copper tube: Interior surface residue limit is 0.0035-g/ft2 (0.038 g/m2)

 ASTM B280 Copper Tube Catalog

Search Item
Standard Dimensions and Weights, and Tolerances in Diameter and Wall Thickness for Straight Lengths
Applicable to drawn temper copper tubes only
Standard Size, in.Outside Diameter, In.(mm)Wall Thickness, in.(mm)Weight, lb/ft (kg/m)Tolerances
Averageoutside diameter, plus and minus, in.(mm)Wallb  thickness, plus and minus, in.(mm)
1/4

0.250 inches

(6.35mm)

0.025 inches

(0.635mm)

0.068 lb/ft

(0.102 kg/m)

0.001 inches

(0.025mm)

0.0025 inches

(0.006mm)

3/8

0.375 inches

(9.52mm)

0.030 inches

(0.762mm)

0.126 lb/ft

(0.187 kg/m)

0.001 inches

(0.025mm)

0.003 inches

(0.08mm)

1/2

0.500 inches

(12.7mm)

0.035 inches

(0.889mm)

0.198 lb/ft

(0.295 kg/m)

0.001 inches

(0.025mm)

0.004 inches

(0.10mm)

5/8

0.625 inches

(15.9mm)

0.040 inches

(1.02mm)

0.285 lb/ft

(0.424 kg/m)

0.001 inches

(0.025mm)

0.004 inches

(0.10mm)

3/4

0.750 inches

(19.1mm)

0.042 inches

(1.07mm)

0.362 lb/ft

(0.539 kg/m)

0.001 inches

(0.025mm)

0.004 inches

(0.10mm)

7/8

0.875 inches

(22.3mm)

0.045 inches

(1.14mm)

0.455 lb/ft

(0.677 kg/m)

0.001 inches

(0.025mm)

0.004 inches

(0.10mm)

1 1/8

1.125 inches

(28.6mm)

0.050 inches

(1.27mm)

0.655 lb/ft

(0.975 kg/m)

0.0015 inches

(0.038mm)

0.004 inches

(0.10mm)

1 3/8

1.375 inches

(34.9mm)

0.055 inches

(1.40mm)

0.884 lb/ft

(1.32 kg/m)

0.0015 inches

(0.038mm)

0.006 inches

(0.15mm)

1 5/8

1.625 inches

(41.3mm)

0.060 inches

(1.52mm)

1.14 lb/ft

(1.70 kg/m)

0.002 inches

(0.051mm)

0.006 inches

(0.15mm)

2 1/8

2.125 inches

(54.0mm)

0.070 inches

(1.78mm)

1.75 lb/ft

(2.60 kg/m)

0.002 inches

(0.051mm)

0.007 inches

(0.18mm)

2 5/8

2.625inches

(66.7mm)

0.080 inches

(2.03mm)

2.48 lb/ft

(3.69 kg/m)

0.002 inches

(0.051mm)

0.008 inches

(0.20mm)

3 1/8

3.125 inches

(79.4mm)

0.090 inches

(2.29mm)

3.33 lb/ft

(4.96 kg/m)

0.002 inches

(0.051mm)

0.009 inches

(0.23mm)

3 5/8

3.625 inches

(92.1mm)

0.100 inches

(2.54mm)

4.29 lb/ft

(6.38 kg/m)

0.002 inches

(0.051mm)

0.010 inches

(0.25mm)

4 1/8

4.125 inches

(105mm)

0.110 inches

(2.79mm)

5.38 lb/ft

(8.01 kg/m)

0.002 inches

(0.051mm)

0.011 inches

(0.28mm)

Notes:

A  The average outside diameter of a tube is the average of the maximum and minimum outside diameters as determined at any one cross section of the tube.

B The tolerances listed represent the maximm deviation at any point.

ASTM B280 ACR Copper Tube Product List

Part NumberOutside DiameterWall ThicknessTheoretcial Weight
Part#: B280ZGK206 | ASTM B280 ACR Copper Tube | Straight pipe | ACR |H58 | HVAC Copper Pipe
206.38mm6.88mm38.56kg/m
Part#: B280WXARC4 | ASTM B280 ACR Copper Tube | Copper pancake coils | ACR |O60 | HVAC Copper Pipe
4.75mm0.76mm0.09kg/m
Part#: B280WXARC19B | ASTM B280 ACR Copper Tube | Copper pancake coils | ACR |O60 | HVAC Copper Pipe
19.10mm0.89mm0.45kg/m
Part#: B280WXARC9C | ASTM B280 ACR Copper Tube | Copper pancake coils | ACR |O60 | HVAC Copper Pipe
9.52mm0.89mm0.22kg/m
Part#: B280WXARC7B | ASTM B280 ACR Copper Tube | Copper pancake coils | ACR |O60 | HVAC Copper Pipe
7.92mm0.81mm0.16kg/m
Part#: B280WXARC22A | ASTM B280 ACR Copper Tube | Copper pancake coils | ACR |O60 | HVAC Copper Pipe
22.30mm0.94mm0.56kg/m
Part#: B280WXARC3 | ASTM B280 ACR Copper Tube | Copper pancake coils | ACR |O60 | HVAC Copper Pipe
3.18mm0.76mm0.05kg/m
Part#: B280WXARC15A | ASTM B280 ACR Copper Tube | Copper pancake coils | ACR |O60 | HVAC Copper Pipe
15.90mm0.71mm0.30kg/m
Part#: B280ZGL66 | ASTM B280 ACR Copper Tube | Straight pipe | ACR |H58 | HVAC Copper Pipe
66.68mm2.03mm3.69kg/m
Part#: B280WXARC7A | ASTM B280 ACR Copper Tube | Copper pancake coils | ACR |O60 | HVAC Copper Pipe
7.92mm0.61mm0.13kg/m
Part#: B280WXARC6B | ASTM B280 ACR Copper Tube | Copper pancake coils | ACR |O60 | HVAC Copper Pipe
6.35mm0.61mm0.10kg/m
Part#: B280ZGK104 | ASTM B280 ACR Copper Tube | Straight pipe | ACR |H58 | HVAC Copper Pipe
104.78mm3.40mm9.69kg/m
Part#: B280WXARC22C | ASTM B280 ACR Copper Tube | Copper pancake coils | ACR |O60 | HVAC Copper Pipe
22.30mm1.65mm0.95kg/m
Part#: B280ZGL104 | ASTM B280 ACR Copper Tube | Straight pipe | ACR |H58 | HVAC Copper Pipe
104.78mm2.79mm8.00kg/m

Free Quotation

Contact info
Product Application